The Akreos Advanced Optics (AO) lens was designed by Bausch + Lomb for excellent stability and excellent vision quality.
Bausch + Lomb's Akreos Adapt AO lens is the world's first aspheric acrylic IOL with aberration neutrality, because the aberrations present in the eye differ from person to person. Unlike other IOLs, it does not add further aberrations to the patient's eye. This leaves the slight, naturally occurring positive aberration from the cornea, providing better depth of field.
Better Vision for More People
- The Akreos Adapt AO is designed to be free of spherical aberration.
- Optical performance is unaffected by optical or anatomical decentration or by pupil size due to uniform centre-to-edge power.1
- More predictable and repeatable refractive outcomes can be expected with a broader patient population.
Aberration-Free Design Helps to Enhance Depth of Field
- The Akreos Adapt AO maintains the natural positive spherical aberrations compared to aspheric aberrated IOLs.
- With its aberration-free design, Akreos Adapt AO helps to significantly improve depth of field in comparison to an aspheric aberrated IOL.
Optimised Effectiveness Against PCO
The Akreos Adapt AO Lens benefits from the unique Square-Edge Technology and a 360° posterior barrier, both features minimising cell migration following implantation.
Fully Single Use Injection System
The Akreos Adapt AO can be injected through the Hydroport-SI single use injector system, enabling in-the-bag implantation of the lens through a 2.8mm phaco incision.
Material
|
26% Acrylic Material with UV absorber
|
Refractive Index
|
1.458 (hydrated)
|
Optic
|
Biconvex aspheric with anterior and posterior surface
|
Optic Size
|
6mm
|
Haptics
|
One piece, four loop, 0° angulation
|
Overall Diameter
|
11.0mm from 0.0 to 15.0 dioptres
10.7mm from 15.5 to 22.0 dioptres
10.5mm from 22.5 to 30.0 dioptres
|
Dioptre Range
|
0.0 to 9.0 in one dioptre increments
10.0 to 30.0 in half dioptre increments
|
A-Constant*
|
Zeiss IOL Master SRK/T = 118.3
Zeiss IOL Master SRK/II = 118.5
US Lens Constants:
|
Applanation A-scan |
Immersion A-scan or IOLMaster* |
A-Constant* |
118.0 |
118.5 |
ACD* |
4.96 |
5.26 |
Surgeon Factor* |
1.22 |
1.51 |
|
ACD*
|
4.96mm
|
Surgeon Factor*
|
1.22
|
Product Order Code
|
ADAPTAO (Lens)
AI-28B (Single use injector)
|
1 G. Lofoco. Influence of Aspheric and Spherical IOLs on Higher-Order Aberrations and Functional Vision: Results of a Comparative Multicenter Study. ASCRS 2006.
*A-constant, ACD and Surgeon Factor are estimates only. It is recommended that each surgeon develop his/her own values. Zeiss IOL Master A-constants sourced from ULIB website